A server has had a drive fail in its storage RAID set.  The 

题目
单选题
A server has had a drive fail in its storage RAID set.  The administrator swaps the drive with a replacement and the RAID set does not automatically start to rebuild the replaced drive.  Which ofthe following utilities would MOST likely be used to initialize the rebuilding of the replace mentdrive?()
A

Net use

B

Array management

C

Fdisk

D

Disk Management Plug-in

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

An administrator has just upgraded a server from non-hot plug storage to all hot plug storage. Theadministrator powers up the server, during POST the RAID controller is recognized but none of the drivelights flash.  Which of the following should the administrator do FIRST to trouble shoot the problem?()

  • A、 Check the backplane cabling.
  • B、 Check the server BIOS.
  • C、 Update the RAID controller firmware.
  • D、 Install the latest hard drive firmware.

正确答案:A

第2题:

A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()

  • A、Replace the drive
  • B、Restore the drive from backup
  • C、Reboot the server
  • D、Reconfigure RAID 5 to RAID 10

正确答案:A

第3题:

A system administrator needs to maintain 1.2TB of storage for a database server. There are six 250GB drives available in the server for storage space. Which of the following RAID configurations would be the BEST choice given that performance and fault tolerance are important factors?()

A. RAID 1 across drive pairs totaling 3 pairs

B. RAID 5 across all 6 drives

C. RAID 10 across all 6 drives

D. RAID 0 across all 6 drives


参考答案:B

第4题:

A system administrator needs to maintain 1.2TB of storage for a database server. There are six 250GB drives available in the server for storage space. Which of the following RAID configurations would be the BEST choice given that performance and fault tolerance are important factors?()

  • A、RAID 1 across drive pairs totaling 3 pairs
  • B、RAID 5 across all 6 drives
  • C、RAID 10 across all 6 drives
  • D、RAID 0 across all 6 drives

正确答案:B

第5题:

Which of the following storage tools could be used to initiate the rebuilding of a failed hard drive?()

  • A、RAID array management
  • B、CHKDSK
  • C、Monitoring agents
  • D、Partitioning management

正确答案:A

第6题:

A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()

  • A、 Edit the boot.ini file.
  • B、 Change to a hardware RAID solution.
  • C、 Recreate the array.
  • D、 Edit the active drive in the array.

正确答案:A

第7题:

Which of the following internal storage technologies has the HIGHEST single drive storage capacity? ()

  • A、 SAS
  • B、 SATA
  • C、 Flash
  • D、 SCSI

正确答案:B

第8题:

An administrator has just upgraded a server from non-hot plug storage to all hot plug storage. The administrator powers up the server, during POST the RAID controller is recognized but none of the drive lights flash.Which of the following should the administrator do FIRST to troubleshoot the problem?()

A. Check the backplane cabling.

B. Check the server BIOS.

C. Update the RAID controller firmware.

D. Install the latest hard drive firmware


参考答案:A

第9题:

A technician manages a server that contains sensitive data. The server currently has two hard drives, one hosting the operating system and other generic files and the second hosting sensitive data. The technician needs to implement a technology that would guard against data loss for only the sensitive data, while adding only one additional hard drive. Which of the following should the technician implement to avoid reformatting any drives?()

  • A、RAID 0
  • B、RAID 1
  • C、RAID 3
  • D、RAID 5

正确答案:B

第10题:

A server connects to iSCSI presented SAN storage array through a dedicated NIC; however, the SAN traffic is passed on the same switches as the Ethernet network and VoIP traffic. The size of the presented drive is 700GB. The administrator has noticed a decrease in storage performance. Which of the following is MOST likely the cause?()

  • A、The server power supply is starting to fail and causing the iSCSI NIC to intermittently lose power.
  • B、There are too many users attempting to access the iSCSI presented disk.
  • C、The other network traffic is causing packet delays in the iSCSI network.
  • D、The SAN is nearing capacity and should be expanded

正确答案:C

更多相关问题