When booting the p5 590 server in full system partition mode

题目
单选题
When booting the p5 590 server in full system partition mode, which location is preferred for the fastest boot?()
A

A SAN device

B

First I/O drawer

C

Any I/O drawer within the main frame

D

First I/O drawer within the expansion frame

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()

  • A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
  • B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
  • C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
  • D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

正确答案:D

第2题:

After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()

  • A、The cfgmgr command was not run to reconfigure the devices
  • B、The machine was not booted into SMS MultiBoot mode after configuration
  • C、The machine was not in full system partition mode when the volume was created
  • D、The alt_disk_install command was not run with the -O option to remove references in the ODM

正确答案:D

第3题:

Companycom has a 16 way 1.65 GHz p5 590 and wants to install a i5/OS partition on their server. The customer wants to keep installation costs to a minimum by sharing devices between all LPARs. Before the operating system can be installed in this partition, the customer was told that there are certain limitations that must be observed. What are these limitations?()

  • A、When the i5/OS partition is housed in the p5 590, the HMC allows seamless installation in a partition as long as the minimum one processor, 256 MB of memory, one Ethernet and one boot adapter/disk is available from internal hardware. 
  • B、V5R3 and later releases of i5/OS can be installed on a POWER5 server partition. Only one processor can be assigned to the i5/OS. A special expansion tower must be ordered. This expansion tower and its devices can be shared with other OS partitions. 
  • C、When the i5/OS partition is housed in the p5 590, the 5250 Twinaxial console must be used to set up the partition. Only one processor can be assigned to the i5/OS partition. A special expansion tower must be ordered to house the IOPs. Devices in the special expansion tower can be shared with other Linux partitions.  
  • D、V5R3 and later releases of i5/OS can be installed on IBM eServer p5 servers. i5/OS can run on two processors in the p5 590. A special expansion tower must be ordered. This expansion tower and its devices cannot be shared with other OS partitions. The iSeries expansion towers are seen by the IBM eServer p5 server as an I/O subsystem.

正确答案:D

第4题:

A system administrator is installing a p5 590 server with an HMC. After pulling the websm client down, it is not possible to connect to the HMC. The HMC can be pinged from the client. Which of the following settings should be verified next?()

  • A、The routes on the HMC
  • B、The firewall setting of the LAN adapter
  • C、The name resolution protocol on the p5 590 server
  • D、The subnet mask settings on the Ethernet adapters

正确答案:B

第5题:

When booting the p5 590 server in full system partition mode, which location is preferred for the fastest boot?()

  • A、A SAN device
  • B、First I/O drawer
  • C、Any I/O drawer within the main frame
  • D、First I/O drawer within the expansion frame

正确答案:B

第6题:

A client has tried to update the firmware of an Ethernet adapter on a p5 590, however it repeatedly fails. What is the most likely cause of this problem?()

  • A、The adapter must be taken offline prior to the firmware update
  • B、The adapter must be assigned to the service partition prior to the firmware update
  • C、The system has not been rebooted since the adapter was added to the Logical Partition
  • D、The adapter must be dynamically removed from the Logical Partition prior to the firmware update

正确答案:A

第7题:

Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()

  • A、POWER5 runs in an SMP mode as default
  • B、POWER5 can run in a full system mode the same as the p690
  • C、POWER5 can run in full system mode with the purchase of PLM
  • D、POWER5 can run in a full system mode, but it is in LPAR mode

正确答案:D

第8题:

Which two statements describe the behavior of the server's SQL mode?()

  • A、The server's SQL mode determines how the server should behave when performing data validation check and interpreting different forms of syntax
  • B、The server's SQL mode determines whether the server should be read-only or should accept commands such as INSERT and UPDATE
  • C、The server's SQL mode can be changed at the session level with a SET SESSION sql_mode="new_value" command
  • D、The server's SQL mode, when globally set on a slave server, applies to events sent from the master

正确答案:A,C

第9题:

Companycom has several AS/400 servers in their IT infrastructure running V5R2 that they wish to consolidate. The customer wants to simplify their environment and install i5/OS on a p5 590 with 16 1.65GHz processors and 20 i5/OS partitions. The customer plans to use the Advanced Power Virtualization to share their storage, processors, and memory. What considerations and limitations should be reviewed with the customer before the purchase?()

  • A、Resources cannot be shared with an i5 partition when it is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. V5R3 OS or later is required. There is a maximum of two partitions in a 590.
  • B、Resources cannot be shared between partitions when i5/OS is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. i5/OS can be at V5R2 or a V5R3. Currently only one i5 partition is allowed. 
  • C、V5R3 is required for the i5 partitions. Virtual IO Server is not supported for the i5/OS partitions to share storage. Up to 10 i5 partitions per processor are allowed (a maximum of two processors for up to 20 partitions). 
  • D、Processor and memory resources can be shared between AIX 5L, Linux and i5/os partitions. i5/OS needs to be at V5R3, and Virtual IO Server is not supported for the i5/OS partition to share storage. On a 1.65 GHz POWER5 p5 590 there is a maximum of one partition.

正确答案:C

第10题:

Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()

  • A、Upgrade the p690 to a p5 590 server running AIX 5.3
  • B、Upgrade the p690 server to AIX 5.3 and implement Advanced Power Virtualization
  • C、Purchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adapters
  • D、Purchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

正确答案:D

更多相关问题