A customer is looking to add disk storage. They are not sati

题目
单选题
A customer is looking to add disk storage. They are not satisfied with their existing EMCCLARiiON CX4-240. Instead of adding storage to the CX4, the customer wants to add a newsystem and migrate the LUNs from the EMC to the new storage system over a 6 month period,and not have any system disruption during this time. They are also interested in consolidating diskstorage management. Given these specifications, which of the following solutions would satisfythis customer’s requirements?()
A

DS5100 and SAN Volume Controller

B

DS5100 and Tivoli Storage Manager

C

2 DS5100 systems with Remote Mirroring

D

DS5100 and Tivoli Storage Productivity Center for Data

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

The customer has recently installed a pSeries p5-570 with EMC attached disk storage.  After installation, the customer complained that the disk access appeared to be too slow.  How should the pSeries technical specialist best assist the customer?()

  • A、Recommend the customer call EMC.
  • B、Recommend the customer call IBM hardware support.
  • C、Recommend the customer contact SupportLine.
  • D、Recommend the customer re-creates the volume groups.

正确答案:C

第2题:

A customer requests a solution that will enhance the availability of their servers and ensure that the time needed to recover from an Operating System fault is at a minimum.  What solution do you recommend? ()

  • A、Use RAID protection and add more memory
  • B、Install Operating System in RAID 0 (Parity) Disk Configuration
  • C、Install Operating System in RAID 5 Disk Configuration
  • D、Use RAID protection and ensure systems are backed-up daily

正确答案:D

第3题:

A customer is looking for a solution to provide high performance storage. A competing vendor has proposed a solution based on a loosely coupled model of 1Gbps iSCSI and SATA disks.What alternative solution could be proposed that is cost-effective and high-performance?()

A. DS8000

B. HDS VSP

C. EMC V-Max standard configuration

D. XIV system 15 module configuration


参考答案:D

第4题:

A customer is looking for a solution to provide high performance storage. A competing vendor has proposed a solution based on a loosely coupled model of 1Gbps iSCSI and SATA disks. What alternative solution could be proposed that is cost-effective and high-performance?()

  • A、DS8000
  • B、HDS VSP
  • C、EMC V-Max standard configuration
  • D、XIV system 15 module configuration

正确答案:D

第5题:

A customer has installed an IBM System Storage DS8700 with 20 TB of storage, two-way processor version, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues.  To address this performance consideration with minimal cost to the customer, which of the following should be the FIRST step to resolve the problem()

  • A、add an expansion frame with additionalFibre Channel ports
  • B、increase the amount of storage by 20 TB
  • C、conduct a Disk Magic study to identify the source of the performance issue
  • D、add additionalFibre Channel ports to the existing DS8700

正确答案:C

第6题:

A customer wants to add a new application to their existing IBM System Storage DS5300. Theyexpect that the new application will require a minimum of 15,000 additional IOPS. What toolshould be used to determine what additional disk is required to effectively add the newapplication?()

  • A、eConfig
  • B、Disk Magic
  • C、Capacity Magic
  • D、Tivoli Storage Productivity Center for Data

正确答案:B

第7题:

A customer is looking to build a virtual desktop infrastructure on an IBM platform. What metric willbe most useful in determining the storage platform recommendation?()

  • A、 type of applications to be used
  • B、 number of users 
  • C、 storage capacity per user 
  • D、 number of IOPS to the disk system

正确答案:D

第8题:

Two file servers have run out of local disk space. The internal drives are at capacity and the company has traditionally only used local disks for storage. Which of the following is the MOST cost effective solution to add storage to both servers?()

  • A、Install fiber cards into the servers and add direct attached storage.
  • B、Install fiber cards into the servers and implement a SAN solution.
  • C、Attach a USB drive to one of the servers.
  • D、Add a NAS to the environment

正确答案:D

第9题:

A customer is looking for a new file and print server and is considering a 2-socket Intel server with redundant power and hard disk that must fit in the current server rack. With 2U available in the rack, the customer is looking for the best price performance ratio.  Which IBM server will fit the best for this customer?()

  • A、x3200
  • B、x3455
  • C、x3550
  • D、x3650

正确答案:C

第10题:

A customer with a single IBM System Storage DS8100 reports severe performance problems for some of their applications when a particular data warehousing application creates a heavy load.  What is the most cost effective way to resolve this issue()

  • A、add additional disks to the DS8100
  • B、add more cache to the DS8100
  • C、move affected volumes to a different disk enclosure
  • D、implement TPC for Disk to monitor performance

正确答案:C