Company.com has a VIO server with a configured virtual Ether

题目
单选题
Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()
A

Run cfgdev on the VIO server and re-run the mkvdev command.

B

Run chdev -a sea_enable=yes on the physical Ethernet adapter.

C

Remove and re-add the virtual Ethernet adapter.

D

Remove the IP address from the physical adapter and re-run the mkvdev command.

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()

  • A、lsmap -all
  • B、lsmap -net
  • C、lsmap -ent
  • D、lsmap -vlan

正确答案:B

第2题:

Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers.  Which of the following commands will identify the Shared Ethernet Adapter mapping?()

  • A、ifconfig -a
  • B、netstat -nr
  • C、lsmap -all -net
  • D、lsdev -Cc adapter

正确答案:C

第3题:

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()

  • A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
  • B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
  • C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
  • D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

正确答案:D

第4题:

Best practices would have no single point of failure between mirrored resources. In setting up virtual, internal boot disks for two client LPARs, how would this be accomplished?()

  • A、Have one VIO server with striped disks for all LPARs
  • B、Have one VIO server with mirrored disks for all LPARs
  • C、Have two VIO servers with each LPAR accessing both VIO servers
  • D、Have two VIO servers with each LPAR accessing a different VIO server

正确答案:C

第5题:

Which of the following has an integrated database?()

  • A、AIX
  • B、IBM i
  • C、Linux
  • D、VIO Server

正确答案:B

第6题:

After rebuilding the list of virtual devices used by the VIO server using the "cfgdev" command, which command would be run to verify that a newly configured virtual SCSI adapter is available?()

  • A、lsdev -virtual
  • B、lsdev -Cs scsi
  • C、lscfg -vl
  • D、lsdev -adapter

正确答案:A

第7题:

An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()

  • A、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
  • B、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name
  • C、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev  rootvg_disk, rmlv rootlv_name
  • D、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl  hdisk#, rmdev -dl vscsi#

正确答案:C

第8题:

While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()

  • A、NPIV and vSCSI both require multipathing in VIO Server only. 
  • B、NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. 
  • C、NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. 
  • D、NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

正确答案:B

第9题:

Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()

  • A、Allocate the CD to the VIO Server and NFS export the CD to the user LPARs
  • B、Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it
  • C、Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device
  • D、Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

正确答案:D

第10题:

Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()

  • A、Shut down all client partitions before updating the VIO server.
  • B、Disconnect the client partitions from any IP networks before updating the VIO server.
  • C、Update the client partitions to the latest OS maintenance level before updating the VIO Server.
  • D、Update the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.

正确答案:A

更多相关问题