In a refrigeration system, if the cooling water to the conde

题目
单选题
In a refrigeration system, if the cooling water to the condenser fails, the().
A

box temperature solenoid valve will close

B

expansion valve will close

C

compressor will shutdown

D

king valve will open

参考答案和解析
正确答案: A
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Low compressor head pressure in a refrigeration system can be caused by ___.

A.insufficient condenser cooling water

B.excessive condenser cooling water

C.air in the refrigeration system

D.excessive refrigerant in the system


正确答案:B

第2题:

High diesel engine cooling water temperatures can be caused by ______.

A.air in the cooling system

B.an overhauled water pump

C.correct amount of coolant

D.no air in the cooling system


正确答案:A

第3题:

What is head tank in the closed cooling water system used for?

A.for the release of air from the cooling water

B.providing expansion room for heated cooling water

C.a place for implementing water and water treatment agent

D.all of the above


正确答案:D

第4题:

单选题
If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().
A

increase the flow of the cooling water through the condenser

B

adjust the high pressure cutout to maintain the desired pressure

C

open the hot gas bypass temporarily to reduce capacity

D

purge non-condensable gases to reduce the excess pressure


正确答案: C
解析: 暂无解析

第5题:

单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


正确答案: A
解析: 暂无解析

第6题:

Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?

A.A shortage of liquid refrigerant.

B.Excessive frost on the evaporator.

C.Excessive condenser cooling water.

D.Insufficient condenser cooling water flow.


正确答案:D

第7题:

Why is it necessary to have routine testing of the cooling water?

A.To ensure that the proper residuals of treatment chemicals, as specified, are maintained all time

B.To trace leakage in the cooling water system

C.It is not necessary

D.To detect the presence of contaminants in the water that may be injurious to the cooling system


正确答案:A

第8题:

If a refrigeration compressor is short cycling on high head pressure, you should

A.purge the condenser if the waterside is dirty

B.check for proper water flow through the condenser

C.increase the high pressure cutout setting

D.reduce the cooling water flow


正确答案:B

第9题:

单选题
In a closed cooling water system, which of the problems can cause the water pressure to fluctuate?()
A

An open vent in the cooling system

B

A fouled sea chest

C

A restricted water passage in the engine

D

Air entrained in the cooling water


正确答案: D
解析: 暂无解析

第10题:

单选题
The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().
A

fresh water expansion tank

B

sea water expansion tank

C

thermostatic expansion valve

D

jacket water cooler accumulator


正确答案: D
解析: 暂无解析