If two AC generators are operated in parallel, the load is d

题目
单选题
If two AC generators are operated in parallel, the load is distributed evenly by()
A

a rheostat

B

a balancing coil

C

changing field excitation

D

adjusting the governor settings

参考答案和解析
正确答案: A
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

You are attempting to parallel two AC.generators, and the synchroscope pointer revolving in the fast direction.This indicates that the frequency of the incoming machine is

A.higher than the bus equency

B.lower than the bus equency

C.the same as the bus frequency but out of phase with it

D.same as the bus frequency and the circuit breaker may be closed at


答案:B

第2题:

When the prime movers of two paralleled generators are equipped with mechanical-hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will .

A.pick up more of any increase in load

B.pick up less of any increase in load

C.share an equal amount of any increase in load

D.drop an equal amount of any decrease in load


正确答案:A

第3题:

How many generators does the shuttle carry?

A.One.

B.Two.

C.Three.

D.Four.


正确答案:C

第4题:

Which data synchronization options between two geographical locations are supported by PowerHA SystemMirror?()

  • A、Parallel and Serial
  • B、Serial and Asynchronous
  • C、Parallel and Synchronous
  • D、Synchronous and Asynchronous

正确答案:D

第5题:

While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.

A.running at the same speed

B.grounded

C.of the same polarity

D.in phase


正确答案:D

第6题:

In which two scenarios do you use SQL* Loader to load data?()

A. Transform the data while it is being loaded into the database.

B. Use transparent parallel processing without having to split the external data first.

C. Load data into multiple tables during the same load statement.

D. Generate unique sequential key values in specified columns.


参考答案:A, D

第7题:

You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine is

A.higher than the bus frequency

B.lower than the bus frequency

C.file same as file bus frequency but out of phase with it

D.the same as the bus frequency, and the circuit breaker may be closed at nay pointer position


正确答案:B

第8题:

( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies.

A.The HVDC (high voltage DC) transmission

B.The EHV (extra-high voltage) AC transmission

C.The AC distribution

D.Generators


参考答案:A

第9题:

The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.

A.load limit settings

B.idle speed settings

C.speed limit settings

D.speed droop settings


正确答案:D

第10题:

单选题
The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().
A

voltage regulators

B

field rheostats

C

reverse power relays

D

prime mover governors


正确答案: C
解析: 暂无解析