Industry standard single 1U, 2U or 3U/4U Intel, AMD, or POWER servers respectively require 600 to 1300 Watt power supplies. What size power supplies is used by the IBM BladeCenter H to power up to fourteen servers, media components, and network switch modules? ()
第1题:
A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server. What is the minimum PowerVM edition that supports the customer requirement?()
第2题:
A network technician is concerned about the environmental effects of power consumption and heat from network resources Limited space is also a concern. Which of the following technologies should be implemented?()
第3题:
A.Power770servers
B.Power750servers
C.Power755servers
D.Power720servers
第4题:
Which of the following is the BEST case scenario for power fault tolerance within a server?()
第5题:
CIOs and their staff have very little experience architecting or designing solutions to support unknown workloads. As executives focus on compliance issues, more systems must be architected to align with emerging or poorly defined requirements. If the customer prefers an integrated solution physically consolidated in a scalable, single framework that can connect to an enterprise class storage area network, what solution would you recommend?()
第6题:
A lightweight access point has been connected to a Catalyst 3550 24-PWR switch, and on power-up the access point fails. What is the problem with the switch?()
第7题:
A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated. The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage. Each system has the following: ? 2 integrated network ports ? 2 fibre channel adapter cards ? 1 power supply and redundant cooling ? HACMP v5.1 In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()
第8题:
下列哪个不是CPU(中央处理单元)()
第9题:
An administrator has a single 14U rack. The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM. Which of the following server types would be BEST suited for this scenario?()
第10题:
Which feature of the IBM p5 servers enables customers to be confident that data within two distinct partitions on the server will be isolated?()