“Flooding back” is a condition where the liquid refrigerant

题目
单选题
“Flooding back” is a condition where the liquid refrigerant ().
A

vaporizes in the condenser

B

reaches the compressor through the suction line

C

flashes in the liquid line

D

condenses in the receiver

参考答案和解析
正确答案: A
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

单选题
A positive displacement pump is that where the volume of the pump chamber is alternately increased to () and then decreased to ().
A

draw the liquid in;force the liquid out

B

force the liquid out;draw the liquid in

C

suction;draw

D

deliver;outlet


正确答案: C
解析: 暂无解析

第2题:

单选题
A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().
A

a shortage of refrigerant in the system

B

air in the system

C

an accumulation of liquid refrigerant in the crankcase

D

a shortage of oil in the crankcase


正确答案: C
解析: 暂无解析

第3题:

To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .

A.suction service valve as a vapor

B.suction service valve as a liquid

C.discharge service valve as a vapor

D.charging valve as a liquid


正确答案:A

第4题:

单选题
A pressure drop through the refrigerant liquid line may cause ().
A

solenoid valve to seize

B

compressor to hunt

C

formation of flash gas in the liquid line

D

expansion valve to freeze open


正确答案: B
解析: 暂无解析

第5题:

单选题
Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().
A

maintain adequate coil back pressure

B

prohibit flashing in the liquid line

C

reduce refrigerant volume in the system

D

reduce compressor discharge line loading


正确答案: A
解析: 暂无解析

第6题:

单选题
Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()
A

Proper refrigerant charge

B

Faulty expansion valve

C

Insufficient refrigerant

D

Solenoid valve stuck open


正确答案: C
解析: 暂无解析

第7题:

单选题
An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
A

restriction in refrigerant piping

B

air and non-condensable gases in the condenser

C

water in the refrigerant

D

flooding back of liquid refrigerant from the evaporator


正确答案: C
解析: 暂无解析

第8题:

If the superheat value of a thermostatic expansion valve is set too low, the _.

A.the suction line will be abnormally cold and liquid may slug back to the compressor

B.the suction line will be hot due to a reduced amount of refrigerant returning to the compressor

C.the temperature of the refrigerant within the condenser will remain the same

D.the temperature of the refrigerant passing through the sub-cooler will decrease


正确答案:A

第9题:

单选题
If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().
A

too much refrigerant in the system

B

oil entrained in the refrigerant

C

less than a full charge of refrigerant in the system

D

ice crystals forming in the refrigerant


正确答案: A
解析: 暂无解析

第10题:

单选题
Foaming of the oil in a refrigeration compressor crankcase is caused by ().
A

refrigerant boiling out of solution from the lube oil

B

liquid refrigerant flooding the compressor and system

C

lube oil viscosity being reduced by refrigerant dilution

D

compressor suction pressure suddenly increasing


正确答案: C
解析: 暂无解析