The boiler water alkalinity in a coil-type auxiliary boiler

题目
单选题
The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()
A

precipitate silica from solution

B

reduce corrosion in the heating coil

C

prevent clogging and erosion in the coil

D

maintain zero water hardness

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

The water in an auxiliary boiler should be tested for chloride content to determine ( ).

A.total dissolved solids

B.salt contamination

C.water harcness

D.chlorine contamination


正确答案:B
解析:chloride:氯
译文:应对辅助锅炉的炉水进行含氯量化验,以判断其是否被海水污染。

第2题:

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.

A.high steam pressure in the boiler

B.abnormally high feed-water temperature

C.abnormally high boiler water temperature

D.steam demand exceeding feed pump capacity


正确答案:B

第3题:

The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .

A.when the boiler has been secured long enough for most solids to settle

B.when the boiler has been cooled to ambient temperature

C.only after raising the water level to within 0.5 inch of the high water cutout only

D.after bypassing the low pressure


正确答案:A

第4题:

单选题
The purpose of the safety relief valves installed on an auxiliary boiler is to ().
A

relieve excess fuel oil pressure during the “off” fire cycle

B

admit water to the dry pipe

C

throttle the forced draft fan output for proper combustion

D

reduce excess steam pressure in the boiler


正确答案: C
解析: 暂无解析

第5题:

单选题
The most common cause of scale formation in an auxiliary boiler is ()
A

concentrations of calcium sulfate in the boiler water

B

fuel oil in the feed water

C

improper treatment of the feed water with calcium sulfate

D

excessive feed water alkalinity


正确答案: C
解析: 暂无解析

第6题:

what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .


正确答案:I have ever used the following brand chemicals :unitor , drew and so on . We should keep the boiler water’s ph scale between 10.5 and 11.5 . If the water become of acidity ( ph scale is below 10 ) ,it is may be caused by following reasons : The water has not been given enough blow down ,or has not been filled enough alkalinity chemicals

第7题:

The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.

A.precipitate(使沉淀) silica (硅石)from solution

B.reduce corrosion in the heating coil

C.prevent clogging and erosion in the coil

D.maintain zero water hardness


正确答案:B

第8题:

The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()

A.salinity is abnormally

B.high steam demand is too

C.feed-water flow is low

D.water level is abnormally low


答案:D

第9题:

单选题
The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()
A

will be modulated in proportion

B

will be modulated in proportion and integral

C

will be modulated in proportion and differential

D

will not be modulated at all


正确答案: C
解析: 暂无解析

第10题:

单选题
In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()
A

The safety valve escape piping should be disconnected from the valve body and a blank inserted

B

The boiler vent valves should be opened

C

All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaks

D

All of the above


正确答案: D
解析: 暂无解析