The safety valve escape piping should be disconnected from the valve body and a blank inserted
The boiler vent valves should be opened
All handhole/manhole covers should be tightened up as much as possible to preclude any leaks
All of the above
第1题:
The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.
A.precipitate(使沉淀) silica (硅石)from solution
B.reduce corrosion in the heating coil
C.prevent clogging and erosion in the coil
D.maintain zero water hardness
第2题:
will be modulated in proportion
will be modulated in proportion and integral
will be modulated in proportion and differential
will not be modulated at all
第3题:
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .
A.when the boiler has been secured long enough for most solids to settle
B.when the boiler has been cooled to ambient temperature
C.only after raising the water level to within 0.5 inch of the high water cutout only
D.after bypassing the low pressure
第4题:
relight the boiler immediately to prevent loss of steam pressure
relight the fire off the brickwork as the bricks are cherry red
purge the furnace of any combustible gases before attempting to relight the fire
speed up the feed pump to prevent dry firing when the burner flame is reestablished
第5题:
relieve excess fuel oil pressure during the “off” fire cycle
admit water to the dry pipe
throttle the forced draft fan output for proper combustion
reduce excess steam pressure in the boiler
第6题:
concentrations of calcium sulfate in the boiler water
fuel oil in the feed water
improper treatment of the feed water with calcium sulfate
excessive feed water alkalinity
第7题:
Receives saturated steam from the generating tubes
Serves as a reservoir of boiler feed water
Holds internal fittings for separation of moisture from steam
Collects steam exhausted from the turbines
第8题:
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.
A.high steam pressure in the boiler
B.abnormally high feed-water temperature
C.abnormally high boiler water temperature
D.steam demand exceeding feed pump capacity
第9题:
The safety valve escape piping should be disconnected from the valve body and a blank inserted
The boiler vent valves should be opened
All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaks
All of the above
第10题:
operating the boiler at less than normal water level
installing fins on the firesides of water-tubes
increasing the amount of excess air to the burners
treating the boiler water with chemical oxygen scavengers