In the () refrigeration compressor one end of the crank shaf

题目
单选题
In the () refrigeration compressor one end of the crank shaft extends through the crankcase house for connection, via a coupling or pulley, to an external drive motor.
A

open-type

B

hermetic

C

semi-hermetic

D

all the above

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Sweating of the refrigeration system compressor crankcase is caused by_______ .

A.too much superheat

B.insufficient superheat

C.suction pressure too low

D.excessive refrigerant returning to the compressor


正确答案:D

第2题:

单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


正确答案: A
解析: 暂无解析

第3题:

If the refrigeration compressor crankcase is sweating, the cause may be due to

A.a shortage of refrigerant

B.the compressor running continuously

C.liquid refrigerant returning to the compressor

D.the compressor short cycling on the high pressure cutout


正确答案:C

第4题:

单选题
If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().
A

a shortage of compressor oil

B

warm food in the refrigerator

C

excessive condenser cooling water

D

a shortage of refrigerant


正确答案: A
解析: 暂无解析

第5题:

单选题
Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().
A

overheated compressor bearings

B

excess lube oil viscosity

C

carbon deposits on the compressor piston rings

D

wax crystals forming in the lubricant


正确答案: A
解析: 暂无解析

第6题:

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.

A.an excess of liquid refrigerant

B.the expansion valve overfeeding

C.a fouled compressor suction strainer

D.the compressor short cycling


正确答案:C

第7题:

单选题
When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().
A

flooding back

B

superheating

C

overflowing

D

recycling


正确答案: C
解析: 暂无解析

第8题:

Low compressor head pressure in a refrigeration system can be caused by ___.

A.insufficient condenser cooling water

B.excessive condenser cooling water

C.air in the refrigeration system

D.excessive refrigerant in the system


正确答案:B

第9题:

单选题
Short cycling of a refrigeration compressor refers to ().
A

frequently grounding out

B

frequently starting and stopping

C

running too fast

D

running too slow


正确答案: C
解析: 暂无解析

第10题:

单选题
()are supplied by main switchboard directly.
A

Suez Canal searchlight, air compressor and air conditioning compressor

B

Air compressor, boiler blower and refrigeration plant

C

Boiler blower, Suez Canal searchlight and refrigeration plant

D

Suez canal searchlight, air compressor and boiler blower


正确答案: C
解析: 暂无解析

更多相关问题