In an operating refrigeration system low on refrigerant, a l

题目
单选题
In an operating refrigeration system low on refrigerant, a liquid line sight glass will()
A

be clear

B

be blue

C

be light green

D

show bubbles

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

单选题
Low compressor head pressure in a refrigeration system can be caused by().
A

insufficient condenser cooling water

B

excessive condenser cooling water

C

air in the refrigeration system

D

excessive refrigerant in the system


正确答案: A
解析: 暂无解析

第2题:

单选题
A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().
A

a shortage of refrigerant in the system

B

air in the system

C

an accumulation of liquid refrigerant in the crankcase

D

a shortage of oil in the crankcase


正确答案: C
解析: 暂无解析

第3题:

Low compressor head pressure in a refrigeration system can be caused by ___.

A.insufficient condenser cooling water

B.excessive condenser cooling water

C.air in the refrigeration system

D.excessive refrigerant in the system


正确答案:B

第4题:

单选题
In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().
A

compressor

B

condenser

C

receiver

D

evaporator


正确答案: D
解析: 暂无解析

第5题:

单选题
In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().
A

compressor;condenser

B

condenser;evaporator

C

throttle valve;evaporator

D

evaporator;condenser


正确答案: D
解析: 暂无解析

第6题:

单选题
A refrigerant boils and vaporizes in the () in a compression refrigeration system.
A

liquid receiver

B

compressor

C

condenser

D

cooling coil


正确答案: A
解析: 暂无解析

第7题:

单选题
In an operating refrigeration system low on refrigerant, a liquid line sight glass will()
A

be clear

B

be blue

C

be light green

D

show bubbles


正确答案: D
解析: 暂无解析

第8题:

Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.

A.carbon deposits on the compressor suction valves

B.the evaporator temperature to increase

C.rapid corrosion of the thermal expansion valve

D.no operating problems


正确答案:B

第9题:

单选题
An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
A

restriction in refrigerant piping

B

air and non-condensable gases in the condenser

C

water in the refrigerant

D

flooding back of liquid refrigerant from the evaporator


正确答案: C
解析: 暂无解析

第10题:

单选题
If a refrigeration system were short of refrigerant, the condition would result in ().
A

continuous running of the compressor

B

high suction pressure

C

high discharge pressure

D

short cycling of the compressor on the water failure switch


正确答案: D
解析: 暂无解析