Which action should be taken when an auxiliary boiler in is

题目
单选题
Which action should be taken when an auxiliary boiler in is operation?()
A

Clean all electrical connections

B

Lift the relief valves by hand

C

Inspect and clean all solenoid valves

D

Inspect for oil and water leaks

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.

A.precipitate(使沉淀) silica (硅石)from solution

B.reduce corrosion in the heating coil

C.prevent clogging and erosion in the coil

D.maintain zero water hardness


正确答案:B

第2题:

Which statement about the inert gas system is TRUE ________.

A.Boiler soot blowers should never be used when the IG system is operating

B.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very light

C.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very light

D.Flue gas with excessive oxygen content is de-oxygenated in the scrubber


正确答案:A

第3题:

The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .

A.when the boiler has been secured long enough for most solids to settle

B.when the boiler has been cooled to ambient temperature

C.only after raising the water level to within 0.5 inch of the high water cutout only

D.after bypassing the low pressure


正确答案:A

第4题:

单选题
The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()
A

will be modulated in proportion

B

will be modulated in proportion and integral

C

will be modulated in proportion and differential

D

will not be modulated at all


正确答案: C
解析: 暂无解析

第5题:

单选题
When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()
A

cold fuel oil

B

low fuel oil pressure

C

low atomizing steam pressure

D

water in the fuel oil


正确答案: C
解析: 暂无解析

第6题:

When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.

A.increase the fuel oil temperature

B.decrease the fuel oil temperature

C.decrease the fuel oil supply pressure

D.increase the air supply


正确答案:D

第7题:

You are testing the external inflation bladder on an immersion suit and find it has a very slow leak.Which action should be taken ________.

A.Replace the suit

B.Replace the inflation bladder

C.Take it out of service and repair in accordance with the manufacturers instructions

D.Some leakage should be expected and a topping off tube is provided; no other action is necessary


正确答案:C

第8题:

The water in an auxiliary boiler should be tested for chloride content to determine ( ).

A.total dissolved solids

B.salt contamination

C.water harcness

D.chlorine contamination


正确答案:B
解析:chloride:氯
译文:应对辅助锅炉的炉水进行含氯量化验,以判断其是否被海水污染。

第9题:

单选题
When installing a hydraulic hose, which of the following precautions should be taken?()
A

The hose should not be twisted

B

The hose should be protected with a sleeve if it is subjected to rubbing

C

There should be some slack in the hose

D

All of the above


正确答案: C
解析: 暂无解析

第10题:

单选题
In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()
A

The safety valve escape piping should be disconnected from the valve body and a blank inserted

B

The boiler vent valves should be opened

C

All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaks

D

All of the above


正确答案: D
解析: 暂无解析