An emergency generator, driven by an internal combustion eng

题目
单选题
An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()
A

week

B

2 weeks

C

month

D

3 months

如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

It ______ for an emergency generator to require paralleling.

A.is not usual

B.is usual

C.is necessary

D.is not impossible


正确答案:A

第2题:

Most pedestal crane power is provided by ______.

A.Electro-hydraulic units

B.Steam units

C.Independent internal combustion power units

D.All of the above


正确答案:A

第3题:

describe the procedure to start an emergency generator ?


正确答案:1) to check the lube oil level in the crankcance and fuel oil level in the tank . 2) to see whether there is any leakage . 3) to check the air pressure if the generator is air started model ; and to check the battery voltage to see whether it is normal if the generator is the battery started model 4)also to make sure there are no obstacles around the machine .

第4题:

单选题
Prior to getting underway,the Master or person in charge of a vessel must().
A

conduct a fire drill

B

conduct a boat drill

C

log the fore and aft draft marks

D

test the emergency generator


正确答案: D
解析: 暂无解析

第5题:

单选题
Each emergency generator on a mobile offshore drilling unit,when tested,must be run under a full load for at least().
A

one hour

B

two hours

C

ten hours

D

four hours


正确答案: B
解析: 暂无解析

第6题:

Prior to getting underway,the Master or person in charge of a vessel must ______.

A.conduct a fire drill

B.conduct a boat drill

C.log the fore and aft draft marks

D.test the emergency generator


正确答案:C

第7题:

What is a requirement for remote manual shutdown stations for internal combustion engine driven cargo pumps on tank barges ________.

A.They must be conspicuously marked

B.They must be located at least 10 feet from the engine

C.There must be at least two such shutdown devices

D.The valve rods shall be fitted with stuffing boxes


正确答案:A

第8题:

The emergency generator or emergency battery is connected to _______on most large ships.

A.distribution boards

B.section boards

C.emergency switch boards

D.main switch boards


正确答案:C

第9题:

单选题
For most diesel propulsion and generator engines, the over-speed trip device will stop the engine by ()
A

moving the governor control to stop

B

shutting off the lubricating oil supply

C

tripping the governor emergency stop lever

D

shutting off the fuel supply


正确答案: D
解析: 暂无解析

第10题:

单选题
A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()
A

an electrical interlock system

B

an automatic paralleling trip switch

C

the synchronizing oscilloscope

D

the reverse current relay


正确答案: D
解析: 暂无解析

更多相关问题