Badly leaking refrigeration compressor discharge valves will

题目
单选题
Badly leaking refrigeration compressor discharge valves will cause().
A

overfeeding of the expansion valve

B

damage to the condenser

C

constant running of the compressor

D

flooding of the receiver

参考答案和解析
正确答案: C
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Badly leaking refrigeration compressor discharge valves will cause ______.

A.overfeeding of the expansion valve

B.damage to the condenser

C.constant running of the compressor

D.flooding of the receiver


正确答案:C

第2题:

单选题
If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().
A

increase the flow of the cooling water through the condenser

B

adjust the high pressure cutout to maintain the desired pressure

C

open the hot gas bypass temporarily to reduce capacity

D

purge non-condensable gases to reduce the excess pressure


正确答案: C
解析: 暂无解析

第3题:

If the refrigeration compressor crankcase is sweating, the cause may be due to

A.a shortage of refrigerant

B.the compressor running continuously

C.liquid refrigerant returning to the compressor

D.the compressor short cycling on the high pressure cutout


正确答案:C

第4题:

单选题
If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().
A

system was overcharged with refrigerant

B

high pressure switch was improperly adjusted

C

expansion valve strainers were fouled

D

suction valves were leaking slightly


正确答案: B
解析: 暂无解析

第5题:

单选题
The unloading system on an air compressor will ().
A

increase compressor discharge pressure on demand

B

increase compressor operating speed as necessary

C

allow the motor to turn the compressor opposed only by friction

D

reduce the compressor frictional load when starting


正确答案: C
解析: 暂无解析

第6题:

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.

A.an excess of liquid refrigerant

B.the expansion valve overfeeding

C.a fouled compressor suction strainer

D.the compressor short cycling


正确答案:C

第7题:

单选题
Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().
A

overheated compressor bearings

B

excess lube oil viscosity

C

carbon deposits on the compressor piston rings

D

wax crystals forming in the lubricant


正确答案: A
解析: 暂无解析

第8题:

The sensing line for the low pressure cutout switch to a refrigeration system is located ______.

A.in the chill box(冰箱)

B.before the receiver

C.on the suction side of the compressor

D.on the discharge side of the compressor


正确答案:C

第9题:

单选题
Insufficient refrigerant in a refrigeration plant may result in ().
A

high discharge pressure

B

frosting of the crankcase

C

high temperature of the overboard water

D

low suction pressure of compressor


正确答案: D
解析: 暂无解析

第10题:

单选题
If a refrigeration system were short of refrigerant, the condition would result in ().
A

continuous running of the compressor

B

high suction pressure

C

high discharge pressure

D

short cycling of the compressor on the water failure switch


正确答案: D
解析: 暂无解析

更多相关问题