单选题Which of the following options applies to virtual Ethernet devices()A A virtual Ethernet adapter can only connect to other partitions within the same system.B A virtual Ethernet  adapter needs  to be connected to an external VLAN  capable switch to be 

题目
单选题
Which of the following options applies to virtual Ethernet devices()
A

A virtual Ethernet adapter can only connect to other partitions within the same system.

B

A virtual Ethernet  adapter needs  to be connected to an external VLAN  capable switch to be able to communicate with other partitions on the same system.

C

A partition can support an unlimited number of virtual Ethernet devices.

D

A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the trunk flag set

参考答案和解析
正确答案: B
解析: 暂无解析
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

Which of the following options applies to virtual Ethernet devices()

  • A、A virtual Ethernet adapter can only connect to other partitions within the same system.
  • B、A virtual Ethernet  adapter needs  to be connected to an external VLAN  capable switch to be able to communicate with other partitions on the same system.
  • C、A partition can support an unlimited number of virtual Ethernet devices.
  • D、A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the "trunk flag" set

正确答案:A

第2题:

Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()

  • A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.
  • B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.
  • C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.
  • D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

正确答案:C

第3题:

After creating a virtual Ethernet adapter in slot #3 of logical partition #5, the user needs to configure the adapter in AIX. Which of the following location codes matches this virtual Ethernet adapter?()

  • A、U9111.520.1000000-V5-C3-T1
  • B、U9111.520.1000000-V3-C5-T1
  • C、U9111.520.1000000-V5-C1-T3
  • D、U9111.520.1000000-V1-C3-T5

正确答案:A

第4题:

The administrator of a Power 595 server is required to concurrently host LPARs for two different customers. Both customers’ LPARs have the same VLAN ID and subnet range, but their traffic must be isolated from each other.  Which feature within the system would provide this functionality?()

  • A、 802.1Q
  • B、 Virtual switch
  • C、 Logical Host Ethernet (LHE) Adapter
  • D、 Shared Ethernet Adapter (SEA) Trunking

正确答案:B

第5题:

When creating a Virtual Ethernet adapter, which of the following steps is done FIRST?()

  • A、Generate a unique MAC address.
  • B、Run cfgmgr to create device special files.
  • C、Create a virtual device with "smitty vlan".
  • D、Add a virtual Ethernet adapter to the partition profile.

正确答案:D

第6题:

A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()

  • A、Shared Ethernet runs on POWER4 systems
  • B、Virtual Ethernet runs on POWER4 systems
  • C、Shared Ethernet requires a Virtual I/O server and Advanced Power Virtualization
  • D、Virtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization

正确答案:C

第7题:

A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()

  • A、Order a 2-port 1Gbps Ethernet LAN adapter.
  • B、Order a 2-port 10Gbps Ethernet LAN adapter.
  • C、Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.
  • D、Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

正确答案:A

第8题:

Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()

  • A、Create two virtual adapters on the client, each one from a separate Virtual IO Server
  • B、Enable dead gateway detection on the client so that the network traffic can be rerouted
  • C、Have a spare network card on standby in the client in case the Virtual IO Server goes down
  • D、Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two  separate Virtual IO Servers

正确答案:A

第9题:

Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()

  • A、Configure a Shared Ethernet Adapter on the Virtual I/O Server.
  • B、Use the same virtual LAN ID on each LPAR.
  • C、Set up IP routing through an LPAR on each system.
  • D、Set up an IP firewall through an LPAR on each system.

正确答案:A

第10题:

Companycom tells the technical sales specialist that recent announcements state that virtual lan in the datacenter is the best option. The customer wants to use interpartition communication to save on adapters and increase performance. The systems are going to have shared and dedicated processor partitions. Some of the partitions will be running AIX 5.2 and some will be running AIX 5.3. The second p5 590 will be running a mixture of AIX 5.3 and Linux partitions with 2.6 kernel. What limitations of vlan/interpartition  communication should be discussed with this customer?()

  • A、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet is supported on AIX 5L and Linux 2.5 and above. 
  • B、Virtual Ethernet can be used within groups of shared OR groups of dedicated processor partitions, but not both simultaneously. Virtual Ethernet comes with AIX 5L, and is supported in AIX 5.2 or AIX 5.3 partitions, but not Linux. 
  • C、Virtual Ethernet can be used in both shared and dedicated processor partitions. Virtual Ethernet can run in an AIX 5.3 or Linux 2.6 Kernel, but not AIX 5.2 partitions. Virtual Ethernet can only connect partitions within a single system. 
  • D、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet can connect partitions between systems if the HMC is shared between systems.

正确答案:C