An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()
第1题:
After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()
第2题:
A user reports that after configuring the BIOS to boot to the hard drive first, the system still tries to boot from the optical drive. Which of the following is the MOST likely cause?()
第3题:
There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives.Which of the following is the MOST likely cause?()
A. A failed RAID controller
B. Two failed processors
C. Two failed sticks of memory
D. Two failed drives
第4题:
A technician is unable to eject a tape from a drive when pressing the eject button. Which of the following is MOST likely the cause?()
第5题:
After a server inspection, an administrator notices a single drive failure on a server configured with RAID 5. Which of the following is the NEXT step to start rebuilding the array?()
第6题:
After performing the initial steps in installing the server OS from a DVD-ROM, the server reboots and goes back into the setup wizard. Which of the following is the MOST likely cause for this problem?()
第7题:
A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive. Which of the following is the MOST likely cause of the failures?()
第8题:
An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()
A. Processor failure
B. Third party memory
C. Disk drive failure
D. ESD during the upgrade
E. Backplane failure
第9题:
A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()
第10题:
A server has had a drive fail in its storage RAID set. The administrator swaps the drive with a replacement and the RAID set does not automatically start to rebuild the replaced drive. Which ofthe following utilities would MOST likely be used to initialize the rebuilding of the replace mentdrive?()