An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()A、Corrupt file system tableB、Backplane failureC、Multiple drive failureD、

题目

An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()

  • A、Corrupt file system table
  • B、Backplane failure
  • C、Multiple drive failure
  • D、Bad cable
如果没有搜索结果或未解决您的问题,请直接 联系老师 获取答案。
相似问题和答案

第1题:

After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()

  • A、Replace the second drive with a hot swappable one.
  • B、Swap the drive boot order in the BIOS
  • C、Make the second disk active under the disk management tool.
  • D、Rebuild the array using the hardware RAID tool at boot.

正确答案:B

第2题:

A user reports that after configuring the BIOS to boot to the hard drive first, the system still tries to boot from the optical drive. Which of the following is the MOST likely cause?()

  • A、Optical drive
  • B、Power supply
  • C、CMOS battery
  • D、CD-ROM disk

正确答案:C

第3题:

There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives.Which of the following is the MOST likely cause?()

A. A failed RAID controller

B. Two failed processors

C. Two failed sticks of memory

D. Two failed drives


参考答案:A

第4题:

A technician is unable to eject a tape from a drive when pressing the eject button. Which of the following is MOST likely the cause?()

  • A、Corrupt OS
  • B、Array is rebuilding
  • C、Driver problem
  • D、Drive failure

正确答案:D

第5题:

After a server inspection, an administrator notices a single drive failure on a server configured with RAID 5. Which of the following is the NEXT step to start rebuilding the array?()

  • A、Reestablish the mirror array.
  • B、Perform online volume expansion.
  • C、Insert hot plug drive.
  • D、Move data to another volume.

正确答案:C

第6题:

After performing the initial steps in installing the server OS from a DVD-ROM, the server reboots and goes back into the setup wizard. Which of the following is the MOST likely cause for this problem?()

  • A、The DVD-ROM drive has failed.
  • B、An installation file copied from the DVD to the hard drive is corrupt.
  • C、Faulty OS installation DVD
  • D、Incorrect boot sequence in the BIOS

正确答案:D

第7题:

A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive.  Which of the following is the MOST likely cause of the failures?()

  • A、 The backplane has failed and needs to be replaced.
  • B、 The array must be disbanded and recreated from a backup source to recognize the replacement drive.
  • C、 There is a conflict with the optical drive on the server.
  • D、 The server power supply is failing and not providing enough power for all the drives.

正确答案:A

第8题:

An administrator has shut down a server to install additional memory. When the administrator restarts the server after the upgrade, it times out. Which of the following could be the cause of the problem?()

A. Processor failure

B. Third party memory

C. Disk drive failure

D. ESD during the upgrade

E. Backplane failure


参考答案:B, D

第9题:

A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()

  • A、 Edit the boot.ini file.
  • B、 Change to a hardware RAID solution.
  • C、 Recreate the array.
  • D、 Edit the active drive in the array.

正确答案:A

第10题:

A server has had a drive fail in its storage RAID set.  The administrator swaps the drive with a replacement and the RAID set does not automatically start to rebuild the replaced drive.  Which ofthe following utilities would MOST likely be used to initialize the rebuilding of the replace mentdrive?()

  • A、Net use
  • B、Array management
  • C、Fdisk
  • D、Disk Management Plug-in

正确答案:B

更多相关问题